PUTAI offers five types of motor starting and driving equipment: high-voltage inverters, solid slip ring starters, medium-voltage liquid soft starters, low-voltage frequency inverters, and low-voltage motor starter cabinets. The product range covers motor starting, soft stopping, and variable-frequency speed control, with published voltage options including 3kV, 6kV, and 10kV for high-voltage applications and 380V and 690V for low-voltage applications.
-
TH-HVF High Voltage Induction InverterThe TH-HVF series High Voltage Induction Inverter cabinet adopts advanced power unit series stacking, vector control and optimized PWM control algorithms, converting 50Hz grid voltage into 0~50Hz
-
TGRJ Solid Slip Ring StarterTGRJ Series Medium & High Voltage Solid-State Soft StartersThe TGRJ series medium & high voltage solid-state Solid Slip Ring Starters are designed for the control and protection of 3~10kV
-
TRQ Liquid MV Soft StarterDesigned to enhance heavy-load starting performance of medium-to-large wound-rotor AC asynchronous motors, the TRQ MV Soft Starter is ideal for industrial applications including building materials,
-
Low Voltage VFD Frequency InverterA VFD Frequency Inverter is a core power control device that leverages advanced frequency conversion and microelectronic technologies to precisely control AC motors by adjusting their operating power
-
Low Voltage VFD Motor StarterThe low-voltage motor VFD Motor Starter cabinet is designed for the start-stop control of high-power motors. It replaces traditional starting methods with soft start technology to achieve smooth
1. Industrial Motor Starters & Drives Product Range
| Product | Main Function | Published Specifications and Features |
|---|---|---|
| TH-HVF High Voltage Induction Inverter | High-voltage motor speed control | 3kV, 6kV, or 10kV input voltage options; variable-frequency output |
| TGRJ Solid Slip Ring Starter | Solid-state motor starting | 3–10kV; 200–15,000kW published power range |
| TRQ Liquid MV Soft Starter | Heavy-duty medium-voltage motor starting | Multiple models covering motor power ranges up to 3,200kW |
| Low Voltage VFD Frequency Inverter | Low-voltage AC motor speed control | 380V / 690V; 0.75–800kW |
| Low Voltage VFD Motor Starter | Low-voltage motor starting and stopping | Six starting modes and two stopping modes |
2. High Voltage Induction Inverter for Industrial Motor Speed Control – TH-HVF
The TH-HVF series is designed for high-voltage induction motor speed control. It uses series-connected power units, vector control, and optimized PWM control.
| Technical Item | Published Specification |
|---|---|
| Input power frequency | 50Hz |
| Output frequency | 0–50Hz (60Hz) |
| Available input voltage | 3kV / 6kV / 10kV |
| System efficiency | ≥98% |
| Power factor | ≥0.95 |
| Output harmonic distortion | Less than 2% |
| Control methods | Vector control and optimized PWM control |
| Fault handling | Power unit fault bypass |
Additional functions include flying start, switching between constant-frequency and variable-frequency operation, and multi-motor master-slave control.
Published applications include fans, pumps, belt conveyors, and elevators.
3. Solid Slip Ring Starter for Medium-Voltage Motor Starting – TGRJ
The TGRJ series uses anti-parallel thyristor modules for solid-state motor starting, with adjustable starting and stopping modes.
| Technical Item | Published Specification |
|---|---|
| Rated voltage | 3–10kV |
| Motor power range | 200–15,000kW |
| Starting current | 2.5–3.5 times rated current |
| Starting time | 0–120 seconds, adjustable |
| Overload capacity | 500% for 30 seconds; 120% continuous |
| Communication interface | RS485 |
| Protection rating | IP4X |
| Cabinet configuration | Cabinet type |
| Cabinet dimensions | 1000 × 1500 × 2300mm (W × D × H) |
| Operating temperature | -25°C to +45°C |
| Installation altitude | ≤1000m; special design required above this altitude |
| Relative humidity | Maximum 95%, non-condensing |
Available starting modes include current-limiting starting, linear voltage ramp, exponential voltage ramp, linear current ramp, and exponential current ramp.
Stopping options include free stopping, soft stopping, braking, soft stopping with automatic braking, and inching operation.
Protection functions include running overcurrent, motor thermal overload, three-phase current imbalance, phase loss, and overheating protection.
The standard published power range is 200–15,000kW. Applications above 5,000kW require special design, and 11kV applications also require special design.
4. Liquid Medium-Voltage Soft Starter for Wound-Rotor Motors – TRQ
The TRQ series is designed for heavy-duty starting of medium-voltage wound-rotor AC asynchronous motors. Published applications include 6kV and 10kV motors in JR, YR, YRKS, and YRKK series.
Medium-Voltage Soft Starter Model Selection
| Model | Applicable Motor Power (kW) | Starting Time (s) | Normal Liquid Operating Temperature (°C) | Maximum Phase Resistance Range (Ω) |
|---|---|---|---|---|
| TRQ4-0.2 | ≤210 | 15±2 | 0–60 | 0.1–2 |
| TRQ4-0.4 | ≤380 | 20±2 | 0–60 | 0.1–2 |
| TRQ4-0.4K(C) | ≤380 | 20±2 | 0–60 | 0.1–2 |
| TRQ6-0.6 | 380–630 | 20±2 | 0–60 | 0.2–3 |
| TRQ6-0.6J | 380–630 | 20±2 | 0–60 | 0.2–3 |
| TRQ6-0.6K(J)/(C) | 280–380 | 20±2 | 0–60 | 0.2–3 |
| TRQ6-1 | 630–1250 | 28±2 | 0–60 | 0.4–3 |
| TRQ6-1W | 630–1250 | 28±2 | 0–60 | 0.4–3 |
| TRQ4-2 | 1250–3200 | 35±2 | 0–60 | 0.3–3 |
Starting Performance
- Starting current: ≤1.3 times rated current.
- Starting torque: ≤1.3 times rated torque.
- Continuous starting capability: 5–10 starts.
- Starting temperature rise: less than 3°C or 5°C, depending on the model.
The model-specific starting time, liquid operating temperature, and phase resistance range should be considered together when selecting a TRQ unit.
5. Low Voltage VFD Frequency Inverter for AC Motor Speed Control
The low-voltage VFD series provides variable-frequency speed control for AC motors.
| Technical Item | Published Specification |
|---|---|
| Available voltage | 380V / 690V |
| Motor power range | 0.75–800kW |
| Applicable motor series | Y, Y2, YE2, YE3, YVP, YVF2, YZ, YBBP |
| Control functions | Sensorless vector control, speed control, and torque control |
| Built-in functions | PLC and PID controller |
| Speed settings | Up to 16 speed stages |
| Protection | Overcurrent, overvoltage, overload, undervoltage, and phase-loss protection |
Additional functions include automatic sleep and wake-up and flexible input and output terminals for control integration.
6. Low Voltage VFD Motor Starter Cabinet
The low-voltage motor starter cabinet provides soft-starting and stopping control for AC motors. Its published configuration includes six starting modes and two stopping modes.
| Technical Item | Published Specification |
|---|---|
| Normal starting frequency | Up to 12 starts per hour |
| Extreme-load starting frequency | 1–2 starts per hour |
| Voltage tolerance | ±15% |
| Cabinet height | 1000–1600mm |
| Cabinet weight | Approximately 30–60kg |
| Control panel | Chinese-language LCD |
| Communication | Supports communication with PLC through common industrial bus protocols |
Adjustable Parameters and Options
The following parameters can be adjusted:
- Starting voltage
- Ramp time
- Initial torque
A dual-speed function is available as an option. The cabinet can also serve as an alternative to conventional star-delta starter cabinets.
7. Motor Starter and Drive Configuration Options
Available configuration options differ by product series.
| Product | Available Options and Customization |
|---|---|
| TH-HVF High Voltage Induction Inverter | External bypass cabinet, PLC remote-control module, industrial touchscreen, customized rated capacity, communication protocol, cooling method, dustproof cabinet, and high-altitude adaptation design |
| TGRJ Solid Slip Ring Starter | Adjustable starting time and starting modes; special design for 11kV and installation altitudes above 1000m |
| TRQ Liquid MV Soft Starter | Multiple models with different motor power and phase resistance ranges |
| Low Voltage VFD Frequency Inverter | Flexible input/output terminals, main or auxiliary speed-setting methods, and PLC control |
| Low Voltage VFD Motor Starter | Adjustable starting voltage, ramp time, and initial torque; optional dual-speed function |
8. PUTAI Motor Equipment Supplier and Product Support
PUTAI Electric Motor Equipment Co., Ltd. supplies AC motors, DC motors, medium-voltage motors, motor starters and drives, motor windings, and related electrical equipment.
Our product range allows customers to source motors, associated control products, spare parts, and accessories through one supplier.
Our company introduction also describes motor design, manufacturing, testing, and after-sales support, as well as export experience covering more than 50 countries.
9. Request a Motor Starter or VFD Quotation
Send us your motor nameplate information, existing equipment specifications, or project requirements to request a quotation for industrial motor starters and drives.
Available information can include:
- Motor rated voltage and power
- Rated current and speed
- Motor type and model
- Starting or speed-control requirements
- Application and load conditions
- Required equipment quantity
You can also send motor nameplate photos, equipment photos, or existing technical drawings. Our team can review the information and identify the corresponding product series and available configuration for your project.
Putai Electric Motor Equipment Co., Ltd. is one of the most professional starters & drivers manufacturers and suppliers in China, also supports customized service with low price. Welcome to buy advanced starters & drivers in stock here from our factory. If you have any enquiry about quotation, please feel free to email us.
